Brand-Specific Electrical vs Hydraulic Diagnostic Flow Charts - How Each Manufacturer Lies Differently (and How to Catch Them)
- RALPH COPE

- 3 hours ago
- 3 min read

VOLVO EXCAVATORS
“If It Feels Weak, It’s Probably Being Told To”
Volvo Diagnostic Reality
Volvo machines are extremely protective.They derate early and aggressively based on sensor input.
Most “hydraulic failures” on Volvo are permission failures, not component failures.
VOLVO-SPECIFIC FLOW
STEP 1: UNDERPERFORMING MACHINE
⬇️
STEP 2: CHECK DERATE STATUS FIRST (NOT LAST)
Engine torque limit active?
Hydraulic power limit active?
➡️ If YES → STOP. Hydraulics are innocent.
⬇️
STEP 3: PRESSURE SENSOR VALIDATION (CRITICAL)
Compare sensor reading vs mechanical gauge
Watch for drift when hot
➡️ Sensor mismatch = fake hydraulic weakness
⬇️
STEP 4: COMMAND vs ACTUAL PUMP STROKE
Volvo often limits pump stroke silently
➡️ Limited stroke with normal pressure capability = electrical control issue
⬇️
STEP 5: CASE DRAIN (ONLY AFTER ELECTRICAL CLEARED)
High case drain = real wear
Normal = stop blaming pump
VOLVO GOLDEN RULE
If a Volvo feels weak but sounds healthy, believe the electronics—not your hands.
KOMATSU EXCAVATORS
“One Bad Signal Creates Ten Fault Codes”
Komatsu Diagnostic Reality
Komatsu machines cascade faults.One incorrect input can trigger multiple unrelated error codes.
Technicians often replace everything except the cause.
KOMATSU-SPECIFIC FLOW
STEP 1: MULTIPLE FAULT CODES PRESENT?
⬇️➡️ YES = suspect ONE signal, not many failures
⬇️
STEP 2: VERIFY LOAD SENSE & PPC PRESSURES
Komatsu load sense errors look like pump failure
➡️ Incorrect LS pressure = system confusion, not wear
⬇️
STEP 3: SENSOR VS MECHANICAL COMPARISON
Komatsu ECUs trust sensors blindly
➡️ Bad sensor = entire machine derates
⬇️
STEP 4: ISOLATE BEFORE REPLACING
Disable valve sections
Block pilot circuits
➡️ Restoration of function = valve or signal issue
⬇️
STEP 5: CASE DRAIN CONFIRMATION
Only condemn pump after LS & sensors cleared
KOMATSU GOLDEN RULE
Multiple fault codes usually mean one liar, not ten broken parts.
DOOSAN / DEVELON EXCAVATORS
“Strong Iron, Weak Signals”
Doosan Diagnostic Reality
Doosan hydraulics are tough.Wiring, connectors, and grounds are not.
Most Doosan “hydraulic failures” start as electrical supply problems.
DOOSAN-SPECIFIC FLOW
STEP 1: CHECK GROUNDS BEFORE ANYTHING
Frame grounds
ECU grounds
Engine grounds
➡️ Poor ground = fake hydraulic failure
⬇️
STEP 2: SOLENOID VOLTAGE UNDER LOAD
Doosan solenoids are sensitive to voltage drop
➡️ Low voltage = weak hydraulics illusion
⬇️
STEP 3: COMMAND STABILITY TEST
Look for fluctuating duty cycles
➡️ Instability = electrical, not hydraulic
⬇️
STEP 4: HYDRAULIC PRESSURE TEST
Doosan pumps rarely fail quietly
➡️ Low pressure with good electrics = real wear
⬇️
STEP 5: CASE DRAIN (CONFIRM ONLY)
High = worn
Normal = stop digging
DOOSAN GOLDEN RULE
If a Doosan hydraulic part failed, prove the electrics didn’t kill it first.
HYUNDAI EXCAVATORS
“Economical Electronics, Honest Hydraulics”
Hyundai Diagnostic Reality
Hyundai machines often suffer from:
Sensor inconsistency
Connector quality issues
Voltage instability
Hydraulics get blamed because electronics fail subtly.
HYUNDAI-SPECIFIC FLOW
STEP 1: SENSOR PLAUSIBILITY CHECK
Pressure sensors
RPM sensors
Temperature sensors
➡️ Inconsistent readings = derate logic triggered
⬇️
STEP 2: COMMAND LIMIT CHECK
Hyundai will quietly limit output without shutdown
➡️ Limited command = electrical issue
⬇️
STEP 3: MECHANICAL PRESSURE CONFIRMATION
Always verify with gauges
➡️ Normal pressure = hydraulics innocent
⬇️
STEP 4: VALVE RESPONSE TEST
Delayed response often electrical, not mechanical
⬇️
STEP 5: CASE DRAIN ONLY IF PRESSURE IS LOW
Don’t jump ahead
HYUNDAI GOLDEN RULE
Hyundai hydraulics don’t “fade.”Electronics quietly tell them to stop working.
CAT (BONUS)
“Electronics Are Honest—But Unforgiving”
CAT Diagnostic Reality
CAT systems are precise.They expect perfect data.
Small deviations cause big reactions.
CAT-SPECIFIC FLOW
STEP 1: DATA VALIDATION
CAT hates borderline sensor values
⬇️
STEP 2: EVENT HISTORY REVIEW
CAT logs problems before failure
⬇️
STEP 3: CONTROL PRESSURE STABILITY
CAT reacts aggressively to instability
⬇️
STEP 4: COMPONENT REPLACEMENT ONLY AFTER CONFIRMATION
CAT parts fail expensively when misdiagnosed
CAT GOLDEN RULE
CAT doesn’t guess.If it reacts, something upstream is wrong.
FINAL UNIVERSAL RULE (ALL BRANDS)
Measure pressure.Verify signal.Confirm case drain.Replace nothing on feel alone.