top of page
Search

VOLVO EXCAVATORS (Why Volvo Hydraulics Get Blamed for Electrical Decisions)

  • Writer: RALPH COPE
    RALPH COPE
  • 2 hours ago
  • 4 min read

Introduction: The Most Misdiagnosed Excavators on Earth


Volvo excavators are not fragile.But they are misunderstood.


More Volvo pumps, valve banks, and motors are replaced unnecessarily than almost any other brand—not because they fail more often, but because Volvo’s electronic protection systems intervene earlier and more quietly than most technicians expect.


If a Volvo feels weak, hesitant, or unresponsive, the odds are high that:

  • The hydraulics are healthy

  • The electronics have limited them


This blog explains how Volvo machines derate, restrict, and protect—and how that behavior tricks even experienced mechanics into condemning good hydraulic components.


How Volvo’s Managed Hydraulics Actually Work

Modern Volvo excavators use:

  • Load-sensing pumps

  • Electronically controlled valve banks

  • Aggressive ECU-based power management


The ECU constantly evaluates:

  • Engine load

  • Hydraulic pressure

  • Oil temperature

  • Sensor plausibility


If anything looks risky, Volvo doesn’t wait for failure.It reduces pump stroke, flow, or engine torque long before damage occurs.


This protection feels exactly like hydraulic wear.


The Classic Volvo Misdiagnosis Pattern

Symptoms

  • Sluggish hydraulics

  • Poor multi-functioning

  • No abnormal noise

  • Machine “feels tired”


What gets blamed

  • Main pump

  • Control valve

  • Swing motor


What’s actually happening

  • Pressure sensor drift

  • Temperature sensor misreporting

  • ECU torque limitation

The hydraulics aren’t failing.They’re being told to behave.


Volvo Pressure Sensors: Small Error, Big Consequence

Volvo pressure sensors are highly influential.


If a sensor:

  • Reads slightly high

  • Drifts when hot

  • Reacts slowly


The ECU assumes:

  • Overload risk

  • Cavitation danger

  • Component stress


Result:

  • Pump stroke reduction

  • Flow limitation

  • Artificial weakness

A mechanical gauge often proves the system is capable—but the ECU refuses to allow it.


Why Volvo Pumps Get Replaced Innocently

Volvo pumps:

  • Rarely fail suddenly

  • Rarely fail quietly


But technicians often skip one critical step:

Command verification

A Volvo pump can be mechanically perfect while being electronically restricted.


If pump command is reduced:

  • Pressure tests lie

  • Performance tests mislead

  • New pumps fail prematurely

Replacing a pump without proving full command availability is how good pumps die young.


Case Drain: When Volvo Finally Tells the Truth

Case drain testing cuts through Volvo’s electronic fog.

  • Normal case drain = pump healthy

  • Elevated case drain = real wear

If case drain is normal and performance is poor:➡️ Stop blaming hydraulics.


Volvo Valve Banks: Rarely the Villain

Volvo valve banks:

  • Are robust

  • Wear slowly

  • Fail honestly


Most “valve problems” are actually:

  • Solenoid voltage issues

  • Signal instability

  • Command restrictions


If isolating a valve section restores performance, the problem is usually control, not metal.


Volvo Diagnostic Golden Rule

If a Volvo feels weak but sounds healthy, prove the electronics are allowing it to work before condemning hydraulics.

Final Volvo Takeaway


Volvo machines don’t fail early.They protect early.


Most Volvo hydraulic replacements are not repairs—they’re misunderstandings.


KOMATSU EXCAVATORS

When One Bad Signal Wrecks the Diagnosis


Introduction: The Cascade Problem

Komatsu excavators are logical, durable, and extremely sensitive to incorrect input.


One incorrect signal can:

  • Trigger multiple fault codes

  • Derate multiple systems

  • Create chaos

Technicians often chase every symptom instead of the original lie.


Why Komatsu Machines Feel “Confused”

Komatsu ECUs:

  • Trust sensors completely

  • React aggressively to inconsistencies


A single bad load-sense signal can create:

  • Pump faults

  • Valve faults

  • Engine derates


Nothing is actually broken—everything is reacting.


Load-Sense Pressure: The Core of Komatsu Confusion

Load-sense (LS) pressure tells the pump how hard to work.


If LS pressure:

  • Is delayed

  • Is incorrect

  • Is unstable


The pump responds incorrectly.


Symptoms:

  • Weak hydraulics

  • Jerky response

  • Overheating


The pump gets blamed.The LS signal started it.


Multiple Fault Codes ≠ Multiple Failures


Komatsu fault cascades follow a pattern:

  1. One sensor lies

  2. ECU loses confidence

  3. Multiple systems derate

  4. Multiple codes appear


Replacing components one by one never fixes the issue.


Komatsu Pump Misdiagnosis Cycle

  • Weak machine

  • Pump replaced

  • No improvement

  • Valve blamed

  • Electronics blamed

  • Customer furious

The original fault was often a single sensor or wiring issue.


Isolation Is Everything on Komatsu

Komatsu machines respond exceptionally well to isolation testing:

  • Block pilot circuits

  • Disable valve sections

  • Compare function behavior

If isolating restores performance, the fault is control-side, not mechanical.


Case Drain on Komatsu: Confirm, Don’t Guess

Komatsu pumps fail honestly.If case drain is high, believe it.If it’s normal, stop digging.


Komatsu Diagnostic Golden Rule

When everything looks broken, one thing is lying.

Final Komatsu Takeaway

Komatsu machines punish guesswork.They reward systematic isolation.


DOOSAN / DEVELON EXCAVATORS

Strong Iron, Weak Signals


Introduction: Built Tough, Wired Cheap

Doosan excavators are mechanically robust.Their hydraulics tolerate abuse.Their electronics often do not.


Most Doosan “hydraulic failures” are electrical supply failures in disguise.


Grounds: The Silent Killer


Doosan ground issues cause:

  • Weak solenoids

  • Erratic valve control

  • Pressure instability


Hydraulics take the blame.Wiring started the crime.


Voltage Drop = Fake Hydraulic Failure

A solenoid receiving:

  • 9–10 volts instead of 12Will move—but weakly.


Result:

  • Slow response

  • Weak force

  • Jerky motion


This feels exactly like hydraulic wear.


Why Doosan Pumps Get Condemned

Doosan pumps are durable.They usually fail loudly.


If a Doosan pump “feels weak” without noise:➡️ Suspect electrics first.


Case Drain Confirms Reality

Normal case drain on a Doosan:

  • Clears the pump

  • Clears the motor

  • Points back to control issues


Doosan Diagnostic Golden Rule

If a Doosan hydraulic component failed, prove the electrics didn’t kill it first.

Final Doosan Takeaway

Doosan failures are rarely mysterious.They’re usually ignored electrical basics.


HYUNDAI EXCAVATORS

When Quiet Electronics Lie Loudly


Introduction: The Subtle Failure Brand

Hyundai machines rarely throw dramatic faults.They quietly limit performance.


Technicians feel hydraulics fade—and blame wear.


Sensor Inconsistency Is the Enemy


Hyundai sensors often:

  • Drift

  • Disagree

  • Degrade slowly


The ECU responds by:

  • Limiting output

  • Protecting systems

  • Never fully shutting down

The result is “weak hydraulics.”


Command Limiting Without Warning

Hyundai machines often:

  • Limit pump output silently

  • Reduce flow gradually

  • Avoid fault codes

Pressure gauges reveal the truth.


Valve Delay ≠ Valve Wear

Delayed response on Hyundai machines is often:

  • Electrical

  • Signal-related

  • Voltage-related

Replacing valve banks rarely fixes it.


Case Drain as Final Authority

Only after:

  • Pressure verified

  • Command verified

Should case drain be used to condemn components.


Hyundai Diagnostic Golden Rule

Hyundai hydraulics don’t fade—electronics quietly tell them to stop.

Final Hyundai Takeaway


Hyundai machines punish assumptions.They reward measurement.

 
 
 

Comments


Workshop Locations

Durban: Cato Ridge

Johannesburg: Fairleads, Benoni

Vikfin logo

Telephone/WhatsApp

083 639 1982 (Justin Cope) - Durban

071 351 9750 (Ralph Cope) - Johannesburg

©2019 by Vikfin (PTY) Ltd. 

bottom of page